18/07/2023

Fire alarm system Salwico Consilium. Troubleshooting

Greetings! In this article, we'll look at some of the problems with the Salwico Consilium fire system on a 10+ year old vessel and how to troubleshoot these issues.

Fire alarm system Salwico Consilium. Troubleshooting

In the official instructions for this system, you can find a lot of information about the problems that occur during the operation of the Salwico fire alarm. But today we will consider only some of them.

Any fire system on a ship is powered by two sources (main switchboard and emergency switchboard, usually 220V), and additional batteries (usually two 12V each, connected in series).

Attention! If you have an old Salwico Consilium fire system on your vessel, avoid turning it off completely, as this may cause it to fail to boot later.

The first problem that happened with this system was error No. 158 BATTERY CABLE / FUSE FAULT